McHaleLogo_Associates-e1588167215642
  • Services
    • Performance
      • Renewables
      • Testing
        • Contractual Acceptance
        • Routine Testing
        • Cooling Tower Testing
      • Improvement
        • Consulting
        • Optimization
        • Monitoring
      • Software
      • Advising
        • Owner’s Engineer
        • Expert Witness
    • Measurement
      • Calibration
      • Instrument Rental
      • Wind Tunnel
      • Natural Gas Fuel Analysis
      • On-site Assistance
      • Consultation
      • Fabrication
    • Power Market
      • Renewables
        • Solar
        • Biofuels
        • Geothermal
        • Hydroelectric
        • Wind
      • Fossil Fuels
        • AQSC
        • Coal
        • Oil & Natural Gas
        • Simple cycle
      • Nuclear
    • Environmental
  • About Us
    • Our History
    • Our Team
    • Our Partners & Clients
  • Projects
  • News
    • Announcements
    • Events & Conferences
    • Tech Pub Library
  • Contact Us
A Real-Time Output-Loss Method for Monitoring Heat Rate for Coal-Fired Power Plants

A Real-Time Output-Loss Method for Monitoring Heat Rate for Coal-Fired Power Plants

by McHale & Associates Inc. | Oct 7, 2022 | Tech Pub Library

ABSTRACT This paper describes a real-time performance monitoring method based on PTC 4-2013 for determining instantaneous heat rate for coal-fired power plants. The calculation protocol uses a modified output-loss approach applied to a control volume that closely...
Exploring a Variant of PTC 4-2013 for Real-Time Performance Monitoring of Fossil Fuel Power Plants

Exploring a Variant of PTC 4-2013 for Real-Time Performance Monitoring of Fossil Fuel Power Plants

by McHale & Associates Inc. | Sep 26, 2022 | Tech Pub Library

ABSTRACT This paper describes a real-time performance monitoring method based on PTC 4-2013 that was developed for determining and reporting annual heat rate for fossil fuel power plants. Unlike for the PTC 4 test, the coal composition is typically not known in...
A Modified F-Factor Approach for Real-Time Performance Monitoring of Fossil Fuel Power Plants

A Modified F-Factor Approach for Real-Time Performance Monitoring of Fossil Fuel Power Plants

by McHale & Associates Inc. | Jul 18, 2022 | Tech Pub Library

ABSTRACT This paper describes a modified F-factor approach for real-time performance monitoring of heat rate and CO2 emissions for fossil fuel power plants. The calculation protocol introduced in the present investigation is a modification of the F-factor method...

Total Solar Field Direct Normal Insolation Measurement Method Under Investigation for ASME PTC 52

by Frank Grotkopf | Oct 30, 2013 | Tech Pub Library

Setting Standards for Solar: ASME’s PTC 52 and the Future of Concentrated Solar Power Testing With an overwhelming push for “green” renewable energy in the recent years, the American Society of Mechanical Engineers (ASME) Performance Test Codes (PTCs) are being called...
Fixed Duct Burner Heat Input Approach for Combined Cycle Power Plant ASME PTC-46 Performance Testing

Fixed Duct Burner Heat Input Approach for Combined Cycle Power Plant ASME PTC-46 Performance Testing

by McHale & Associates Inc. | Feb 28, 2012 | Tech Pub Library

ABSTRACT Since its publication in 1996, ASME PTC 46 Performance Test Code on Overall Plant Performance has established itself as the premier test code for conducting overall plant performance within the power industry, especially for combined cycle power plants. The...
Consideration of Co-Variance in Power Plant Test Uncertainty Calculations

Consideration of Co-Variance in Power Plant Test Uncertainty Calculations

by McHale & Associates Inc. | Apr 21, 2009 | Tech Pub Library

ABSTRACT One of the most important aspects of American Society of Mechanical Engineers (ASME) Performance Test Code (PTC) thermal performance testing is the proper determination of test uncertainty since the Uncertainty Analysis (UA) validates the quality of a test as...
« Older Entries
Next Entries »

Subscribe Our Newsletter

  • This field is for validation purposes and should be left unchanged.

Recent Posts

  • Staying in the Green: Why Regulatory Compliance Matters in Geothermal Power
  • Acceptance Testing Isn’t the Finish Line — It’s the Benchmark That Powers High-Value O&M
  • Powering Up: How Technology Upgrades Future-Proof Geothermal Plants
  • McHale Team Attending 2026 CTI Annual Conference
  • Performance guarantees aren’t optional—and neither is the partner you choose to validate them
Contact Us
About Us

Project Map

Request More Info

  • This field is for validation purposes and should be left unchanged.

McHale & Associates


Telephone Number

+1-865-588-2654



Email Address

sales@mchale.com

}

Hours of Operation

Monday – Friday
8:30 AM – 7:30 PM (ET)

 



Corporate Office - Redmond, WA

8561 154th Avenue NE, Suite 210
Redmond, WA 98052

FAX: +1-425-991-8480

Monday – Friday
7:30 AM – 4:30 PM (PT)



Knoxville, TN

4700 Coster Road
Knoxville, TN 37912

FAX: +1-865-934-4779

Monday – Friday
8:30 AM – 5:30 PM (ET)

Copyright 2023.  McHale & Associates, Inc. – All Rights Reserved | Sitemap
  • Follow
  • Follow
  • Follow