WIND TUNNEL SPECS

OPERATIONAL

  • 24” x 24” x 60” Test Section
  • Free stream Velocity = (170 – 4900 FPM / 0.86 – 25 m/s)
  • Inlet Conditioning
  • Interchangeable Ports to Accommodate Nearly All Equipment Mounting Requirements
  • Window Ports to Allow for Non Intrusive Measurements

TEST EQUIPMENT

  • Computer-Controlled 2-Axis Automated Traverse System
  • High-Accuracy Micromanometers
    (+0.0025” H20 / +0.6221 Pa)
  • High-Frequency Data Acquisition
    (Maximum 50,000 Samples / Sec; Total for DAQ)
  • Bullnose Probe
  • Replaceable Cartridge Upstream of Test Section Inlet to Allow for Studies in Turbulent Fields

CALIBRATION CAPABILITIES

  • EPA Method 2 Pitot Probes
  • EPA Method 5 Pitot Probes
  • Anenometers
  • Multi-ported Pitot Probes

WIND TUNNEL

Services

WHAT ARE THE WIND TUNNEL’S CAPABILITIES?

The facility is an open circuit low-speed low turbulence wind tunnel with 2 ft x 2 ft x 6 ft testing section and includes a 10:1 inlet contraction section installed with diffusion screens. A belt-driven motor outfitted with a variable frequency drive allows for continuous airflow velocities with precision flow control. The test section has 2-axis traverse systems, allowing for detailed flow studies of any 3-D model. The test section is also equipped with glass walls, allowing for non-intrusive flow measurements as the customer requires.

For multi-ported probes, the facility is equipped with a height-adjustable workbench with predetermined angled mounting points to calibrate yaw, pitch, and roll accurately. Coupled with McHale’s ISO 17025 certified calibration laboratory, the facility has highly accurate temperature, pressure, and differential transmitters, customizable to the customer’s requirements.

WOULD YOU LIKE TO LEARN MORE?

CONTACT US TO DISCUSS HOW WE CAN ASSIST YOU WITH YOUR WIND TUNNEL CALIBRATION NEEDS.

duta manuh